Fibre cement EQUITONE façade materials are fibre cement sheeting manufactured in compliance with AS/NZS 2908.2 (Cellulosecement products Part 2: Flat sheets) and ISO 8336 (fibre-cement flat sheets).
Weatherproofing Performance Requirement FP1.4 and P2.2.2 of the NCC: EQUITONE façade systems have been tested and certified to AS 4284 for the purpose compliance with the relevant Performance Requirements of the NCC.
Structural Performance Requirement B1.2 & B1.4, and P2.1.1 of the NCC: EQUITONE façade materials may be used in all wind zones including C & D - cyclonic areas - in accordance with AS 4040.3 (7.99KPa).
Non-combustibility & fire properties Performance Requirement C1.9 and P2.3.1 of the NCC: EQUITONE façade materials are deemed non-combustible as per the Deemed-to-Satisfy Provisions of C1.9(e) & 3.7.1.1(d) of the NCC. Performance Requirement C1.10 of the NCC Volume 1: EQUITONE façade materials are classified as a Group ‘1’ fire resistant material in accordance with AS 5637.1, and are compliant with AS 1530.3.